Vks Xr-2124 12 Volt 4 Terminal Continuous Duty 200 AMP Solenoid Fits Sbj6255 686696200681
◆ Low power consumption
◆ High sensitivity
◆ Miniature,light weight
◆ Fit for automatic remote control,communication devices,RF control,toys,etc.
◆ Dimension: 15.5*11*11.5mm
◆ It is railway signaling relays
Description
We provide our employees with a broad space for development, and we hope that all kinds of talents who are willing to devote themselves to spst automotive relay, 40 ampere AC relay, 40a 12v Relay industry will join our team. Because of the high quality and competitive price of our products, we will be the market leader. For more information, please feel free to contact us. Premium products and excellent customer service have always been the cornerstone of our success, we will use our products to provide convenient solutions for your needs.
1 Product Survey of 5 ampere communication relay
◆ Low power consumption
◆ High sensitivity
◆ Miniature,light weight
◆ Fit for automatic remote control,communication devices,RF control,toys,etc.
◆ Dimension: 15.5*11*11.5mm
◆ It is railway signaling relays
Designation way
BS401 12 S C 20
1 2 3 4 5
1, Model No.: BS401
2, Rated Coil Voltage: 5V, 6V, 9V, 12V, 24V(DC)
3, Package Type: S: Sealed
4, Contact Form: A:NO B:NC C:SPDT
5, Coil Power Consumption: 20:0.2W, 36:0.36W, 45:0.45W
2 Parameter diagram of 5 ampere communication relay
| Contact Rating | |||
| Contact Form | 1A:NO; 1B:NC; 1C:SPDT | ||
| Contact Material | Ag AgNi | ||
| Contact Load Capacity | 1A, 2A,3A, 5A/125VAC,30VDC | ||
| Switching Power Max. | 90W 375VA | ||
| Switching Voltage Max. | 60VDC 250VAC | ||
| Switching Current Max. | 5A | ||
| Contact Resistance | ≤100mΩ | IEC 255-7 3.12 | |
| Life expectancy | Electrical | 10 5 | IEC 255-7 3.30 |
| Mechanical | 10 7 | IEC 255-7 3.31 | |
Coil Rating(20℃) | |||||||
Rated Coil Voltage (VDC) | Coil Voltage Max. | Pick up(<VDC) | Drop out (>VDC) | Coil Resistance (1±10%)Ω | Power (W) | Operate Time (ms) | Release Time (ms) |
3 | 3.3 | 2.25 | 0.3 | 45 | 0.2 | ≤5 | ≤5 |
5 | 5.5 | 3.75 | 0.5 | 125 | |||
6 | 6.6 | 4.5 | 0.6 | 180 | |||
9 | 9.9 | 6.75 | 0.9 | 405 | |||
12 | 13.2 | 9.0 | 1.2 | 720 | |||
24 | 26.5 | 18.0 | 2.4 | 2880 | |||
3 | 3.3 | 2.25 | 0.3 | 25 | 0.36 | ≤5 | ≤5 |
5 | 5.5 | 3.75 | 0.5 | 69.4 | |||
6 | 6.6 | 4.5 | 0.6 | 100 | |||
9 | 9.9 | 6.75 | 0.9 | 225 | |||
12 | 13.2 | 9.0 | 1.2 | 400 | |||
24 | 26.5 | 18.0 | 2.4 | 1600 | |||
3 | 3.3 | 2.25 | 0.3 | 20 | 0.45 | ≤5 | ≤5 |
5 | 5.5 | 3.75 | 0.5 | 56 | |||
6 | 6.6 | 4.5 | 0.6 | 80 | |||
9 | 9.9 | 6.75 | 0.9 | 180 | |||
12 | 13.2 | 9.0 | 1.2 | 320 | |||
24 | 26.5 | 18.0 | 2.4 | 1280 | |||
Technical Rating | ||
Insulation Resistance | Min.100MΩ(500VDC) | IEC 255-5 |
Dielectric Strength | ||
Between contacts | 50Hz 500VAC 1min | IEC 255-5 |
Between contacts and coil | 50Hz 1000VAC 1min | IEC 255-5 |
Shock Resistance | 100m/s 2 11ms | IEC 68-2-27 test Ea |
Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc |
Leading-out Terminal Strength | 5N | IEC 68-2-21 test Ua1 |
Weldability | (235±2)℃ ,(3±0.5)s | IEC 68-2-20 test Ta way 1 |
Ambient Temperature | ﹣30℃~70℃ | |
Relative Humidity | 85%(40°) | IEC 68-2-3 test Ca |
Weight | 3.5g |
Technical Rating | ||
Insulation Resistance | Min.100MΩ(500VDC) | IEC 255-5 |
Dielectric Strength | ||
Between contacts | 50Hz 500VAC 1min | IEC 255-5 |
Between contacts and coil | 50Hz 1000VAC 1min | IEC 255-5 |
Shock Resistance | 100m/s 2 11ms | IEC 68-2-27 test Ea |
Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc |
Leading-out Terminal Strength | 5N | IEC 68-2-21 test Ua1 |
Weldability | (235±2)℃ ,(3±0.5)s | IEC 68-2-20 test Ta way 1 |
Ambient Temperature | ﹣30℃~70℃ | |
Relative Humidity | 85%(40°) | IEC 68-2-3 test Ca |
Weight | 3.5g |
3 Dimension and electrocircuit of 5 ampere communication relay

Outline Dimensions

Bottom View Layout

Wiring Diagram(Bottom View)
Engineering Data

4. FAQ
Q: Can you do OEM and ODM?
A: Yes, OEM and ODM are both acceptable. The material, color, style can customize, the basic quantity we will advise after we discuss.
Q: Can we be your agent?
A: Yes, welcome to cooperation with this. We have big promotion in the market now. For the details please contact with our overseas manager.
The company provides solutions to the needs of customers around the world with personalized customization, allowing the Vks Xr-2124 12 Volt 4 Terminal Continuous Duty 200 AMP Solenoid Fits Sbj6255 686696200681 to add unique elements and becoming more vivid and rich, which greatly enhance the added value of products. Over the years, we have worked hard to promote the transformation of enterprises from small to large, from single structure to diversified operation, and from rapid development to strong enterprise. Based on our value concept, we make the greatest possible effort to integrate the realization of corporate value with the realization of employee value when formulating corporate development goals.
Hot Tags: 5 ampere communication relay, China, suppliers, manufacturers, factory, made in China, 40 ampere AC relay, TUV power relay, apfc relay, 4 pin relay 40 amp, 4kv between contact and coil, fitness equipment relay
You Might Also Like