Contact Us
- 1289 Tanjialing West Road, Lanjiang Street, Yuyao City, Zhejiang Province, China
- humphreyzhu@nbc-relays.com
- +86-574-62824561

PCB Relay Orginal Crst90 Alternative Relay AC110V 220 240 30A Spst 832 Switching Capability
◆ Coil insulation level Class F
◆ Dust-proof&Sealed type
◆ Agree with RoHS-Directive
◆ Dimension: 32*27.2*28.5mm & 32*27.2*20.5mm
◆ Its a kind of PCB and Quick terminal AC relay
Description
The company will continue to develop and update more technologies and products, uphold the business philosophy of "integrity, professionalism, and win-win", adhere to the principle of customer first, quality first, and better serve the development of the spdt automotive relay, ac dc relay, electrical protection relays industry . We will continue to enhance our corporate innovation capability by vigorously promoting the building of our values of innovation and continuous improvement. We continue to improve the company's environmental image and realize the harmonious development of the company's economy and environment.
1 Product Survey of ac pcb relay
Product Features :
◆High load switching ability:40A
◆2500VAC is acceptable for isolation strength between contact and coil
◆ Coil insulation level Class F
◆ Dust-proof&Sealed type
◆ Agree with RoHS-Directive
◆ Dimension: 32*27.2*28.5mm & 32*27.2*20.5mm
◆ Its a kind of PCB and Quick terminal AC relay
Model Name principle indication, see below.
NB901 E -220 S -S -A L T-105℃ Φ3.1 X
1 2 3 4 5 6 7 8 9 10
1: Relay Model 2: NO max load 30A, none: 40A 3: Coil rated voltage 4: package S: Sealed, D: dust proof.
5: Contact Material: S:AgSnO2 C:AgCdO 6: Contact Form: A:Normally Open B:Normally Close C:SPDT(NO&NC)
7: L: Height of shell 20.5mm None:Height of shell 28.5mm 8: T-105℃: ambient temperature 105℃ none: normal ambient temperature
9: Φ3.1: Quick terminal hole dia. 3.1mm None: Quick terminal hole dia. 1.6mm 10: X: customer used code
Overview
Our Ac Pcb Relay has a beautiful appearance and adopts a high-quality shell with high strength, high temperature resistance, corrosion resistance and good flame retardancy. Silver alloy contact has good conductivity and long service life. Reliable pull in, which can effectively reduce open circuit and short circuit. We focus on the production of relays for many years, fully automated production equipment and professional R & D personnel to escort the quality.
Our Ac Pcb Relay has high-grade material shell, exquisite and beautiful, high strength, high temperature resistance, corrosion resistance, strong flame retardancy and long service life. Silver alloy contact has good conductivity and long service life. Reliable pull in, which can effectively reduce open circuit and short circuit. Our relays are cost-effective. We have complete models and technical support.
2 Figure form of ac pcb relay
| Contact Rating | ||||
| Contact Form | 1A,1B,1C | |||
| Contact Material | AgCdO AgSnO2 | |||
| Contact Load Capacity | NB901 | NB901E | ||
| 40A 240VAC/30VDC 40A 277VAC 1.5HP 1HP 240VAC TV-5 TV-15 | 30A/20A 240VAC/30VDC 30A 277VAC 1HP 1/2HP 240VAC TV-5 | |||
| Switching Power Max. | 1200W 11000VA | |||
| Switching Voltage Max. | 30VDC/277VAC | |||
| Switching Current Max. | 40A | |||
| Contact Resistance Max. | 50mΩ(1A ,24VDC) | |||
| Life expectancy | Electrical | 40A: 2x104 30A: 2x104 | ||
| Machanical | 10 7 | |||
Safety Certification | ||
Approval | CQC | UL |
Load | 40A 240VAC 30VDC | 40A 277VAC 1.5HP 240VAC, TV-5 |
| Coil Rating | ||||
| Coil Voltage | Coil Resistance Ω±10% | Pick up (VDC) Max. (75% of Rated Voltage) | Drop out (VDC) Min.(10% of Rated Voltage) | |
| Rated | Max. | |||
| 24 | 31.2 | 120 | 18 | 7 |
| 110 | 143 | 2360 | 83 | 33 |
| 120 | 156 | 3040 | 90 | 36 |
| 220 | 286 | 13490 | 165 | 66 |
| 240 | 312 | 13490 | 180 | 72 |
| 277 | 360 | 15000 | 208 | 83 |
| Technical Rating | |||
| Insulation Resistance | Min.1000MΩ(500VDC) | IEC 60255-5 | |
| Dielectric Strength | Between Contacts | 1500VAC, 50/60Hz 1min; Max 4000 VAC | IEC 60255-5 |
| Between Coil&Contact | 2500VAC 50/60Hz Min; | IEC 60255-5 | |
| Operate Time | ≤15ms | ||
| Release Time | ≤10ms | ||
| Shock Resistance | Operation extremes 10G Damage limits 100G | IEC 68-2-27 test Ea | |
| Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc | |
| Ambient Temperature | ﹣55℃~85℃;﹣55℃~105℃ | ||
| Relative Humidity | 85% RH , 40℃ | IEC 68-2-3 test Ca | |
| Weight | Approx.26.0g | ||
| Package | Sealed;Dust-proof type | ||
3 Dimension and electrocircuit of ac pcb relay

Outline Dimensions

Bottom View Layout
Wiring Diagram(Bottom View)


Engineering Data
4.Frequently Asked Question
Q: Do you have a export licence?
A: Yes.
Q: What is your frequent used payment term?
A: Normally customer should pay 50% of contract, then we start production. Before shipment customer should pay balance of order.
As the market demand for PCB Relay Orginal Crst90 Alternative Relay AC110V 220 240 30A Spst 832 Switching Capability continues to grow, our company continues to develop more valuable products. Top quality is our life. We maintain the existing core competitive advantages, and create the best products and professional service.
Hot Tags: ac pcb relay, China, suppliers, manufacturers, factory, made in China, Vehicle Relays, 20a 12v relay, power interrupter relay, spdt 24v flasher relay, 20 ampere power relay, five ampere sensitive signal relay