◆2500VAC is avaliable for dielectric strength between contact and coil
◆ Coil insulation grade Class F
◆ Contact form 1A,1B,1C available
◆ Dust-proof&Sealed type
◆ Complies with RoHS-Directive
◆ Dimension: 50.2*27.2*28mm
Description
In the future, we will continue our efforts to dedicate quality and affordable 5 amp 12 volt relay, 24v Spst Relay, 5 pin ac relay to meet the requirements of our customers. We continue to cultivate active talents and dedicated service standards through increasingly improved management systems. Our manpower promotion strategy is to take performance, ability, development potential, diligence and dedication as the main principles of promotion to achieve the common development of the company and employees.
1 Product Recommendation of 40 ampere water pump relay
Product Features :
◆High load switching capability
◆2500VAC is avaliable for dielectric strength between contact and coil
◆ Coil insulation grade Class F
◆ Contact form 1A,1B,1C available
◆ Dust-proof&Sealed type
◆ Complies with RoHS-Directive
◆ Dimension: 50.2*27.2*28mm
◆ It Can replace Songchuan's similar relay with model No. 832AW/855AW/832HAW
◆ It can be used for water pump relay
Overview
Our Water Pump Relay adopts high-quality composite silver contacts with strong conductivity and large carrying current. According to customer needs, we can customize the materials suitable for resistive load, inductive load or capacitive load contacts. It has high-quality coils, which have good performance in melting resistance, mechanical and heat resistance, softening and breakdown, and high voltage resistance.
It is safe to use and has tens of millions of product configurations. It is the choice of more customers and reliable. Our Water Pump Relay adopts high-quality copper coil, and the mechanical life can reach more than 100000 times. With the rapid development of industrial automation, automotive electronics and home appliance industries, the performance requirements of relays are also changing. A single load type can no longer meet the needs of people's daily life. We have many types of relays for customers to choose.
2 Parameter chart of 40 ampere water pump relay
| Contact Rating | ||||
| Contact Form | 1A,1B,1C | |||
| Contact Material | AgCdO AgSnO2 | |||
| Contact Load Capacity | NB904 | NB904E | ||
| 40A 240VAC/30VDC 40A 277VAC 1.5HP 1HP 240VAC TV-5 TV-15 | 30A/20A 240VAC/30VDC 30A 277VAC 1HP 1/2HP 240VAC TV-5 | |||
| Switching Power Max. | 1200W 11000VA | |||
| Switching Voltage Max. | 30VDC/277VAC | |||
| Switching Current Max. | 40A | |||
| Contact Resistance Max. | 50mΩ(1A ,24VDC) | |||
| Life expectancy | Electrical | 40A: 2x104 30A: 105 | ||
| Machanical | 10 7 | |||
Safety Certification | |||
Approval | CQC | TUV | UL |
Load | 30A/40A 240VAC 30VDC | 30A/40A 240VAC 30VDC | 30A/40A 277VAC 1.5HP 1HP 1/2 HP 240VAC TV-5 TV-15 |
| Coil Rating | ||||||||||||
| 900mw | 600mw | |||||||||||
| No. | Coil Voltage | Coil Resistance Ω±10% | Pick up (VDC) Max. (75% of Rated Voltage) | Drop out (VDC) Min.(10% of Rated Voltage) | No. | Coil Voltage | Coil Resistance Ω±10% | Pick up (VDC) Max. (75% of Rated Voltage) | Drop out (VDC) Min.(10% of Rated Voltage) | |||
| Rated | Max. | Rated | Max. | |||||||||
| 5 | 5 | 6.5 | 28 | 3.75 | 0.5 | 3 | 3 | 3.9 | 15 | 2.25 | 0.3 | |
| 6 | 6 | 7.8 | 40 | 4.5 | 0.6 | 5 | 5 | 6.5 | 42 | 3.75 | 0.5 | |
| 9 | 9 | 11.7 | 90 | 6.75 | 0.9 | 6 | 6 | 7.8 | 60 | 4.5 | 0.6 | |
| 12 | 12 | 15.6 | 160 | 9 | 1.2 | 9 | 9 | 11.7 | 135 | 6.75 | 0.9 | |
| 15 | 15 | 19.5 | 250 | 10.25 | 1.5 | 12 | 12 | 15.6 | 240 | 9 | 1.2 | |
| 18 | 18 | 23.4 | 360 | 13.5 | 1.8 | 15 | 15 | 19.5 | 375 | 10.25 | 1.5 | |
| 24 | 24 | 31.2 | 640 | 18 | 2.4 | 18 | 18 | 23.4 | 540 | 13.5 | 1.8 | |
| 48 | 48 | 62.4 | 2560 | 36 | 4.8 | 24 | 24 | 31.2 | 960 | 18 | 2.4 | |
| 110 | 110 | 143 | 13445 | 82.5 | 11 | 48 | 48 | 62.4 | 3840 | 36 | 4.8 | |
| Technical Rating | |||
| Insulation Resistance | Min.1000MΩ(500VDC) | IEC 60255-5 | |
| Dielectric Strength | Between Contacts | 1500VAC, 50/60Hz 1min; Max 4000 VAC | IEC 60255-5 |
| Between Coil&Contact | 2500VAC 50/60Hz Min; | IEC 60255-5 | |
| Operate Time | ≤15ms | ||
| Release Time | ≤10ms | ||
| Shock Resistance | Operation extremes 10G Damage limits 100G | IEC 68-2-27 test Ea | |
| Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc | |
| Ambient Temperature | ﹣55℃~85℃;﹣55℃~105℃ | ||
| Relative Humidity | 85% RH , 40℃ | IEC 68-2-3 test Ca | |
| Weight | Approx.32.0g | ||
| Package | Sealed;Dust-proof type | ||
3 Measurement and circuitry of 40 ampere water pump relay

Outline Dimensions

TOP View Layout

Wiring Diagram(Bottom View)

Engineering Data
4.FAQ
Q. Can we print our own logo?
A. Yes,we offer OEM service.
Q: Which port do you load goods ?
A: We load goods on ningbo port which is very near to our city.
Our company keeps up with the changes of technology, market and user demand, and constantly develops innovative Meishuo Me100-S-1A-Xf 277VAC Normally Open Type 1.5mm Contact Clearance PCB Latching Relay. The code of conduct of enterprise ethics is the concrete action of enterprise morality and the code of action for the practice of enterprise moral concept. We believe that innovation creates the future, and uphold the faith of innovation, sharing, cooperation and win-win.
Hot Tags: 40 ampere water pump relay, China, suppliers, manufacturers, factory, made in China, engine starter motor relay, 4 pin 10 amp relay, 12v relay switching 240v, 5 amp 12 volt relay, Pcb Power Relay, 40a 220v ac relay
You Might Also Like