Contact Us
- 1289 Tanjialing West Road, Lanjiang Street, Yuyao City, Zhejiang Province, China
- humphreyzhu@nbc-relays.com
- +86-574-62824561

30kw 37.5kVA Diesel Generator Powered by Cummins Yangdong Isuzu Weichai Engine
◆ Miniature size, low coil power dissipation
◆ NO contact loading capacity 20A
◆ PC board installing directly
◆ Provide Low halogen and low bromine
◆ Suitable for situation with high surge current, such on household appliances, automated system ,electronic equipments,meters,TV-5 remote control TV receiver,CCTV instrument,sound equipments,etc.
◆ Size: 20.3x16.5x20.5mm
Description
From the perspective of market demand, our company works hand in hand with enterprises to solve various problems encountered in production. Relying on scientific research and technology, we produce various high-quality water heater relay, 5 volt 12 amp relay, 25 ampere power relay. The company takes a pragmatic attitude, boldly innovates, strives for perfection, and continuously develops high-quality products. We pursue high efficiency and high quality work, and enjoy the professional quality of happiness and satisfaction in the work. The management philosophy is the concrete embodiment of the corporate vision, mission and core values in the management.
1 Product Presentation of SPST 12v 5 pin relay
Product feature:
◆ Miniature size, low coil power dissipation
◆ NO contact loading capacity 20A
◆ PC board installing directly
◆ Provide Low halogen and low bromine
◆ Suitable for situation with high surge current, such on household appliances, automated system ,electronic equipments,meters,TV-5 remote control TV receiver,CCTV instrument,sound equipments,etc.
◆ Size: 20.3x16.5x20.5mm
◆ It Can replace Tyco's similar relay with model No. SRUDH
Definition for this model (See below)
Name rule :
922 12VDC SL C W H
1 2 3 4 5 6
1 Model No.:922
2 Rated Coil Voltage:3,6,9,12,15,18,24,48VDC
3 Package Type:SL Sealed None:Dust-Proof
4 Contact Form: A:1A; B:1B; C:1C
5 W: white None:black
6 loading ability 16A/17A/20A
2 Information chart of SPST 12v 5 pin relay
| Contact Rating | |||
| Contact Form | 1A(SPSTNO),1B(SPSTNC),1C(SPDT(B-M)) | ||
| Contact Material | AgCdO AgSnO2 | ||
| Dielectric Strength | Between Coil&Contact | 2500VAC/1min | |
| Between Contacts | 1000VAC/1min | ||
| Contact Load Capacity | Resistive Load:20A/277VAC;20A/250VAC;20A/125VAC;17A/277VAC,16A /250VAC Lamp Load:TV-8,TV-5 120VAC, 240VAC | ||
| Switching Power Max. | 480W 5540VA | ||
| Switching Voltage Max. | 24VDC 277VAC | Switching Current Max.:20A | |
| Contact Resistance Max. | ≤100mΩ | IEC 61810-7 4.12 | |
| Life expectancy | Electrical | 5x10 4 | IEC 61810-7 4.30 |
| Machanical | 10 7 | IEC 61810-7 4.31 | |
| Coil Rating | ||||||||||
| No. | Coil Voltage(VDC) | Coil ResistanceΩ±10% | Pick up (VDC) Max. (75% of Rated Voltage) | Drop out (VDC) Min.(10% of Rated Voltage) | Power (W) | Operate Time (ms) | Release Time (ms) | |||
| Rated | Max. | |||||||||
| 005-360 | 5 | 6.5 | 69 | 3.75 | 0.5 | 0.36 | ≤15 | ≤5 | ||
| 006-360 | 6 | 7.8 | 100 | 4.5 | 0.6 | |||||
| 009-360 | 9 | 11.7 | 225 | 6.75 | 0.9 | |||||
| 012-360 | 12 | 15.6 | 400 | 9 | 1.2 | |||||
| 018-360 | 18 | 23.4 | 900 | 13.5 | 1.8 | |||||
| 024-360 | 24 | 31.2 | 1600 | 18 | 2.4 | |||||
| 048-360 | 48 | 62.4 | 6400 | 36 | 4.8 | |||||
| 005-450 | 5 | 6.5 | 69 | 3.75 | 0.5 | 0.45 | ≤15 | ≤5 | ||
| 006-450 | 6 | 7.8 | 80 | 4.5 | 0.6 | |||||
| 009-450 | 9 | 11.7 | 180 | 6.75 | 0.9 | |||||
| 012-450 | 12 | 15.6 | 320 | 9 | 1.2 | |||||
| 018-450 | 18 | 23.4 | 720 | 13.5 | 1.8 | |||||
| 024-450 | 24 | 31.2 | 1280 | 18 | 2.4 | |||||
| 048-450 | 48 | 62.4 | 5120 | 36 | 4.8 | |||||
| 012-600 | 12 | 15.6 | 240 | 9 | 1.2 | 0.6 | ≤15 | ≤5 | ||
| 024-600 | 24 | 31.2 | 960 | 18 | 2.4 | |||||
Technical Rating | ||
Insulation Resistance | Min.100MΩ(500VDC) | IEC 60255-5 |
Shock Resistance | 10G 11ms | IEC 68-2-27 test Ea |
Vibration Resistance | 10Hz~55Hz double amplitude 1.5mm | IEC 68-2-6 test Fc |
Leading-out Terminal Strength | 10N | IEC 68-2-21 test Ua1 |
Weldability | 250℃±3℃ 3s±0.5s | IEC 68-2-20 test Ta Way1 |
Ambient Temperature | ﹣40℃~105℃ | |
Relative Humidity | 85%(40℃) | IEC 68-2-3 test Ca |
Weight | About 14.0g | |
Safety Certification | |||
Approval | CQC | UL | TUV |
Load | NO:15A/250VAC | 20A 277VAC/20A 125VAC/17A 277VAC/TV-8 TV-5 | 20A 250VAC 16A 250VAC |
3 Measurement and electrocircuit of SPST 12v 5 pin relay

Outline Dimensions Bottom View Layout

Wiring Diagram(Bottom View)

Engineering Data
4.FAQ
Q: Do you provide sample ? Is it free?
A: If the sample is low value, we will provide the free sample with freight collect. But for some high value samples, we need to collect the sample charge.
1.If l don't know what kind of the product I need, what should I do?
A: Just take it easy,you just need to provide us technical parameters of relays which you are looking for.
We adopt modern management mechanism, take 'unity, pragmatism, honesty, innovation' as the core concept of the enterprise, and 'high-quality products, high-quality service' as the corporate goal, and try our best to make a contribution to the development of the 30kw 37.5kVA Diesel Generator Powered by Cummins Yangdong Isuzu Weichai Engine industry. The company has established a strict quality management system and implemented strict service quality standards. We have been working diligently ever since to embrace the needs of our global customer base. We work to ensure absolute customer satisfaction. Our team has dedicated itself to perfecting our three core components, 'Service, Management and Craftsmanship'.
Hot Tags: SPST 12v 5 pin relay, China, suppliers, manufacturers, factory, made in China, 24v contactor relay, Automotive Timer Relay, 4 pin 10 amp relay, monitoring instrument relay, screw relay, car fuel pump relay
You Might Also Like