+86-574-62824561

Latest Products

  • NB160 SUBMINIATURE GENERAL POWER RELAY 40A D109V
  • NB160 SUBMINIATURE GENERAL POWER RELAY 32A D116V
  • NB160 SUBMINIATURE GENERAL POWER RELAY 60A 003V
  • NB160 SUBMINIATURE GENERAL POWER RELAY 32A 003V
  • NB160 SUBMINIATURE GENERAL POWER RELAY 40A 003V
  • NB160 SUBMINIATURE GENERAL POWER RELAY 50A D109V

Contact Us

12V 24V Diesel Starter Relay Jd134 Start Relay Jd234 EQ153 12VDC 24V Jd123

12V 24V Diesel Starter Relay Jd134 Start Relay Jd234 EQ153 12VDC 24V Jd123

◆ Dust-proof&Sealed type
◆ In accordance with RoHS-Directive
◆ Dimension: 32*27.2*20mm
◆ Support coil voltage 24V, 110V, 220V,240, 277V

Description

Talent and innovation are the source of our sustainable development. The group has a professional R&D team for the integrated development of 12v relay switching 240v, schneider power relay, hair dryer relay production, education and research. We have greatly improved the quality assurance capability of our products, and quality and innovation are the cornerstones of our business. High quality, high requirements, high quality and high efficiency are our purposes, customer satisfaction is our goal, and using professional technology to make professional products is our philosophy. We have distribution networks in many places and sales teams with rich marketing experience.

1 Product Introduction of ac current relay

Product Features :

◆ High load switching capability: 40A

◆ 2500VAC&4000VAC is valid for isolating strength between contact and coil

◆ Coil insolation Rank Class F

◆ Contacts forms NO,NC&SPDT

◆ Dust-proof&Sealed type

◆ In accordance with RoHS-Directive

◆ Dimension: 32*27.2*20mm

◆ Support coil voltage 24V, 110V, 220V,240, 277V


Relay model Defining guide :

NB90  E  -220  S  -S  -A  4  W  4KV  L  T-105℃   X

  1    2   3   4  5    6  7  8    9   10    11     12


1:  Relay Model    2: NO max load 30A, none: 40A   3: Coil rated voltage  4: package S: Sealed, D: dust proof.


5:  Contact Material: S:AgSnO2  C:AgCdO  6:  Contact Form:   A:Normally Open  B:Normally Close  C:SPDT(NO&NC)

7:  Pin Form: A4:Normally open(4 pins), A5:Normally open(5 pins); B4:Normally close(4 pins), B5:Normally colse(5 pins);  C5:SPDT(5 pins), C6:SPDT(6 pins). 


8: W: white None: black  9:  4KV: Dielectric Strength between contact and coil 4000VAC  none: Dielectric Strength between contact and coil 2500VAC

10: L: coil power consumption 600mW, none: 900mW    11: T-105℃: ambient temperature 105℃   none: normal ambient temperature

12:  X: customer used code





Overview

Every detail is designed carefully, focusing on quality, making products carefully and using them for a long time. Ac Current Relay is suitable for overload and open phase protection of AC 50Hz three-phase motor. The relay can protect the motor with a starting time of up to 90 seconds. The relay adopts LED nixie tube display, which has the obvious advantages of intuitive display, convenient use, small volume, simple installation and so on.


Our Ac Current Relay is applicable to production lines such as printing, packaging, plastics, food and metallurgy, and occasions requiring remote observation data and automatic control of production process. It is compact and easy to use and install. Reading is intuitive and clear without conversion. It is widely used and has won a good reputation.


2 Parameter form of ac current relay

Contact Rating
Contact Form1A,1B,1C
Contact MaterialAgCdO AgSnO2
Contact Load CapacityNB90NB90E
40A 240VAC/30VDC 40A 277VAC 1.5HP 1HP 240VAC TV-5 TV-1530A/20A 240VAC/30VDC 30A 277VAC 1HP 1/2HP 240VAC TV-5
Switching Power Max.1200W 11000VA
Switching Voltage Max.30VDC/277VAC
Switching Current Max.40A
Contact Resistance Max.50mΩ(1A ,24VDC)
Life expectancyElectrical40A: 2x104 30A: 2x104
Machanical10 7

Safety Certification



Approval

CQC

UL

Load

40A 240VAC 30VDC

40A 277VAC 1.5HP 240VAC, TV-5

Coil Rating
Coil VoltageCoil Resistance Ω±10%Pick up (VDC) Max. (75% of Rated Voltage)Drop out (VDC) Min.(10% of Rated Voltage)
RatedMax.
2431.2120187
11014323608333
12015630409036
2202861349016566
2403121349018072
2773601500020883


Technical Rating
Insulation ResistanceMin.1000MΩ(500VDC)IEC 60255-5
Dielectric StrengthBetween Contacts1500VAC, 50/60Hz 1min; Max 4000 VACIEC 60255-5

Between Coil&Contact2500VAC 50/60Hz Min; (4000VAC Min without Pin #6,when required)IEC 60255-5
Operate Time≤15ms
Release Time≤10ms
Shock ResistanceOperation extremes 10G Damage limits 100GIEC 68-2-27 test Ea
Vibration Resistance10Hz~55Hz double amplitude 1.5mmIEC 68-2-6 test Fc
Ambient Temperature﹣55℃~85℃;﹣55℃~105℃
Relative Humidity85% RH , 40℃IEC 68-2-3 test Ca
WeightApprox.26.0g
PackageSealed;Dust-proof type


3 Dimension and circuit of ac current relay

32

Outline Dimensions


33

Bottom View Layout


34

Wiring Diagram(Bottom View)


35

Engineering Data


4.FAQ

Q: How far is your factory from the airport and train station?

A: From Shanghgai airport about 3 hours by car, and from train station about 20 minutes.

We can pick up you.


Q: Can you provide similar relay from other branded company?

A: Yes we can provide.


With an excellent reputation and many years experience within the industry, we can offer you a wide range of high quality 12V 24V Diesel Starter Relay Jd134 Start Relay Jd234 EQ153 12VDC 24V Jd123 to meet your business needs. Since its establishment, the company has always been guided by technology and based on quality. We have always been recognized by the industry with our high-end quality products and professional technical support.

Hot Tags: ac current relay, China, suppliers, manufacturers, factory, made in China, Quick terminal and Flange cover relay, vacuum cleaner relay, TV remote controller relay, 12v 5 Pin Relay, power off delay relay, relay 220v 40a

Send Inquiry